Coda® Positive Pressure Unit

Home » Products » LifeGlobal Group » CodaAir filters » Coda® Positive Pressure Unit

Coda® Positive Pressure Unit

 
CAPP-115 (For 115V)
CAPP-230 (For 230V)

     
 

CPPS-001

Semi-Annual Filter Kit: Change 6 months after initial/annual kit.
4 Canisters on plate, 2” Prefilter, 4” Prefilter

 

CPPA-001

Annual Filter Kit: Change 6 months after semi-annual kit.
4 Canisters on plate, 2” Prefilter, 4” Prefilter, 6” HEPA

Intended Use   The unique design and concept of the CodaAir® + Positive Pressure Unit reduce VOCs in the air of the IVF laboratory. High quality activated carbon and potassium permanganate act to efficiently absorb all VOCs and aldehydes, reducing their effect on embryos, gametes and embryologists.
     
General Information   Human Embryos deserve Safe and Proven Technologies specially designed and manufactured for IVF in ISO Certified 13485 medical facilities.

Operating Security: Rigorous design specifications have been applied in the development of the CodaAir® System + Positive Pressure Unit to ensure maximum air purification. The CodaAir® + Positive Pressure Unit reduces the presence of VOCs, bacteria/fungal spores and all particulate matter using a 4-stage filtration system. The design of the unit assures continuous removal of VOCs and particulates in the laboratory.

Highly Effective and Proven System for Removing VOCs: The unique design and concept of the CodaAir® + Positive Pressure Unit reduce VOCs in the air of the IVF laboratory. High quality activated carbon and potassium permanganate act to efficiently absorb all VOCs and aldehydes, reducing their effect on embryos, gametes and embryologists.

Air Quality Issues: CodaAir® + Positive Pressure Unit helps with off-gassing of new materials. Furniture, paint, adhesives, plastic packaging and cleaning supplies all release detrimental levels of VOCs. The CodaAir® + Positive Pressure Unit removes them and circulates fresh, clean air into the laboratory.

Pollution and Photochemical Smog: In a typical IVF laboratory there may be high levels of VOCs and CACs. Sources can range from air pollution, hospital activities to construction. Current AIA standards for “positive air pressure” require three (3) fresh air changes per hour. The CodaAir® + Positive Pressure Unit has a fresh air turnover rate of 18.75 times per hour in a 200 sq ft, 1600 cu ft room (18.58 sq m, 45.31 cu m) and 6.25 times per hour in a 600 sq ft, 4800 cu ft room (55.74 sq m, 135.9 cu m), providing the cleanest possible environment for embryos.

HEPA is not enough! …Only activated carbon can remove VOCs: CodaAir® effectively removes VOCs. VOCs are too small to be removed by HEPA filtration alone.
     
Recommendations for Use   For a full and detailed User Manual for the Coda® Positive Pressure Unit please contact us at customerservice@lifeglobal.com.

     
Precautions and Warnings   Warning: To avoid risk of electrical shock, this equipment must only be connected to a supply mains with protected earth.

Caution: No modification of this equipment is allowed.

Caution: Do not place the unit in a damp area, in water or under an open window. This may cause damage to the unit.

Caution: Damage to the Coda® Positive Pressure Unit will occur if the unit is put in a damp area, in water or under an open window. Do not operate the Coda® Positive Pressure Unit if it appears to have been dropped or damaged. Federal (U.S.A.) law restricts this device to sale, distribution, or use by or on the order of a licensed medical practitioner.